Commercial charging projects can require very different power levels, installation formats, connector standards and user-access methods. Nexora ECO organizes AC and DC charging hardware around the site requirement, target market and project operating model.

AC & DC product familiesOCPP 1.6J on selected platformsMulti-standard project optionsOEM / configuration support
Supplier-catalogue product forms
Integrated commercial DC charging station family
Commercial AC wallbox charger
Wall mounted DC charging station
AC to High-Power DCFrom wallbox and shared AC platforms through integrated and liquid-cooled DC systems.
Connector MatchingGB/T, CCS2, CCS1, CHAdeMO and regional AC connector directions are available across selected product families.
Connected ControlSelected catalogue platforms list OCPP 1.6J with Ethernet and cellular communication options.
Project ConfigurationPower, quantity, installation, payment, branding and documentation are confirmed before production.
APPLICATIONS

Different sites need different charging strategies.

Start with how the site operates: who charges, how long vehicles stay, how many vehicles arrive, what electrical capacity is available and whether access or payment control is needed.

Workplaces & Offices

Employee and visitor charging where dwell time is predictable and AC charging can often cover daily use.

Hotels & Destination Sites

Longer parking windows with a mix of guest convenience, controlled access and optional branding requirements.

Retail & Commercial Parking

Shared charging locations where turnover, parking duration and payment or access logic may shape the product mix.

Fleet & Depot

Charging plans organized around route windows, vehicle return times, simultaneous demand and expansion planning.

Public & Highway Charging

Higher-throughput sites where integrated DC or high-power systems are typically evaluated against traffic and dwell time.

Mixed-Use Developments

Projects combining AC destination charging with faster DC charging for visitors, tenants, fleets or public users.

COMMERCIAL HARDWARE

Choose the product family by site requirement.

The product forms below are taken from the supplied manufacturer catalogues already used across the Nexora ECO product pages. Final specifications are confirmed for the exact selected platform.

AC wallbox charging station
AC Destination Charging

Commercial AC Wallbox

Wall-mounted AC charger family for workplaces, hospitality, parking and mixed commercial sites.

3.5 / 7 / 11 / 22 kW on selected Type 2 seriesWi-Fi / Bluetooth options on selected modelsEthernet / RFID / OCPP options on selected seriesIndoor / outdoor catalogue applications
Dual output AC charging station
Shared AC Charging

Dual-Output AC Charging

Dual-connector AC hardware for shared locations where two vehicles may need to charge from one installed unit.

2 × 11 kW / 2 × 22 kW catalogue familyAC 400 V7 in LCD / touch LCD on selected seriesOCPP / RFID / Ethernet options
Small DC charging station
Compact DC

Small DC Charging Station

Compact wall- or column-mounted DC charger for lower-power applications and sites with limited installation footprint.

YLC-KC-7 family7 kW catalogue listing4.3 in color touch displayOCPP 1.6J / IP55 listed
Wall mounted DC charging station
Wall-Mounted DC

Wall-Mounted DC Charging

Compact commercial DC platform for wall or column mounting where a smaller footprint is preferred.

YLC-KC-20 / KC-30 / KC-40 familyAC 380 V input7 in touch displayOCPP 1.6J / IP55 listed
Integrated DC charging station product family
Integrated Fast Charging

Integrated DC Charging Station

Floor-standing commercial DC charger family for public, parking, fleet and larger project deployments.

60 / 80 / 120 / 160 / 180 / 240 / 320 / 360 kW200–1000 V outputGB/T / CCS2 / CCS1 / CHAdeMO optionsOCPP 1.6J / communication options
Liquid cooled high power charging stack
High-Power DC

Liquid-Cooled Charging Stack

High-power flexible charging architecture for large public sites, rest stations, parking hubs and other high-demand projects.

240–960 kW catalogue range150–1000 VDC2 / 4 / 6 / 8 / 10 / 12 charging portsOCPP 1.6J / IP55 listed
POWER PLANNING

Use power level as a project decision—not just a product label.

The catalogue spans destination AC charging, compact DC, integrated fast charging and high-power liquid-cooled systems. Actual selection should be matched to electrical capacity, dwell time and expected simultaneous charging demand.

Destination AC7–22 kWTypical direction for workplaces, hotels and longer-dwell commercial parking. Selected Type 2 catalogue series also include 3.5 kW.
Compact DC7 kWSmall DC family shown for lower-power wall or column installation.
Wall DC20 / 30 / 40 SeriesCompact wall-mounted DC product family listed as YLC-KC-20 / 30 / 40.
Integrated DC60–360 kWFloor-standing family covering multiple commercial fast-charging power levels.
High-Power Stack240–960 kWLiquid-cooled flexible charging stack with multiple charging-port configurations.
CONTROL & CONNECTIVITY

Confirm the operating logic before confirming the charger.

Commercial hardware may need simple plug-and-play operation, controlled user access, QR or card start, remote monitoring or payment integration. These functions vary by product family and should be confirmed against the final configuration.

OCPP 1.6JListed on selected AC and DC catalogue platforms for remote management integration.
Ethernet / CellularEthernet and 2G / 3G / 4G options are shown on selected DC products.
RFID / QR / APPStartup and access methods depend on the selected platform and project requirements.
Payment OptionsSelected commercial DC catalogue products show card or QR payment directions.
Connector StandardConfirm vehicle market and charging-standard requirements before production.
OEM & Project BrandingHousing, logo, interface and packaging requests are reviewed model by model.
Multi-standard all-in-one commercial charging station
REFERENCE PROJECTS

Supplier catalogue reference installations.

These project references come from the supplied charging-system manufacturer catalogue. They are shown as production and deployment references for the product supply network, not as independently audited Nexora ECO project claims.

Tajikistan public gas station charging project
Tajikistan · Public Gas StationsCatalogue reference: 33 pcs 120 kW two-gun DC chargers.
Tajikistan highway charging project
Tajikistan · Highway SiteCatalogue reference: 9 pcs customized 120 kW two-gun DC chargers.
Uzbekistan resort charging project
Uzbekistan · ResortCatalogue reference: 42 pcs 120 kW two-gun DC chargers.
Russia EV charging station project
Russia · Two Charging StationsCatalogue reference: 27 pcs 60 / 80 kW DC chargers per station, 54 total.
Iraq charging project
Iraq · Group CompaniesCatalogue reference: 15 pcs 160 kW two-gun DC chargers.
Final project suitability, certification scope, grid requirements, payment integration and connector configuration must be confirmed for the destination market and exact order.
PROJECT WORKFLOW

From site requirement to production-ready configuration.

A commercial charging inquiry becomes much easier to quote when the site information, charging target and operating logic are confirmed first.

01

Define the Site

Country, application, parking layout, expected users and project quantity.

02

Confirm Power

Available electrical capacity, desired charging speed and simultaneous demand.

03

Match Standards

Vehicle connector standard, communication, access and payment requirements.

04

Lock Configuration

Product family, options, branding, documentation, quantity and quotation scope.

05

Production & QC

Order follow-up, inspection, packing and shipment preparation against the approved configuration.

FAQ

Commercial charging project questions

Should we choose AC or DC charging for a commercial site?

It depends mainly on dwell time, daily vehicle turnover, electrical capacity and the charging objective. Longer-stay sites can often use more AC charging; higher-turnover or public sites may require DC charging. Mixed AC + DC configurations are also possible.

Can you support OCPP and network communication?

Selected catalogue platforms list OCPP 1.6J together with Ethernet and cellular communication options. The exact supported functions should be confirmed for the selected model and software requirement.

Which connector standards are available?

The supplied product catalogues include Type 2, Type 1 / J1772, NACS, GB/T, CCS2, CCS1 and CHAdeMO directions across different product families. Availability varies by charger type and configuration.

Can the charger housing, logo or interface be customized?

Private-label and project customization can be reviewed model by model. Branding, housing color, interface, cable/connector, packaging and selected functions should be confirmed before quotation and sample approval.

What information should we send for a commercial project quotation?

Send the target country, application, estimated quantity, preferred AC/DC power level, connector standard, communication or payment requirements, branding needs and project timeline. Site electrical information is also useful when available.

Send the site requirement. We will match the charging direction.

Tell us the country, application, estimated quantity, target power, connector standard and any OCPP, payment or branding requirements. Final configuration is confirmed before quotation and production.

WhatsApp